Step
1540-12
The
system
stopped
with
the
Please
define
the
System
Console
prompt
appearing
on
the
system
console.
Standalone
diagnostics
can
be
booted.
Perform
the
following:
1.
Follow
the
instructions
on
the
screen
to
select
the
system
console.
2.
When
the
DIAGNOSTIC
OPERATING
INSTRUCTIONS
screen
is
displayed,
press
Enter.
3.
If
the
terminal
type
has
not
been
defined,
you
must
use
the
Initialize
Terminal
option
of
the
FUNCTION
SELECTION
menu
to
initialize
the
AIX
operating
system
environment
before
you
can
continue
with
the
diagnostics.
This
is
a
separate
operation
from
selecting
the
firmware
console
display.
4.
Select
Advanced
Diagnostic
Routines
.
5.
When
the
DIAGNOSTIC
MODE
SELECTION
menu
displays,
select
System
Verification
and
run
diagnostics
on
all
resources.
Did
running
diagnostics
produce
a
different
symptom?
NO
Go
to
substep
6
of
“Step
1540-9”
on
page
115.
YES
Go
to
“Entry
MAP”
on
page
71.
Use
the
new
symptom.
6.
Record
any
devices
missing
from
the
list
of
all
adapters
and
devices.
Continue
with
this
MAP.
When
you
have
fixed
the
problem,
use
this
record
to
verify
that
all
devices
appear
when
you
run
System
Verification.
Are
there
any
devices
missing
from
the
list
of
all
adapters
and
devices?
NO
Reinstall
all
remaining
adapters,
if
any,
and
reconnect
all
devices.
Return
the
system
to
its
original
configuration.
Be
sure
to
select
fast
boot
mode
(select
enable
fast
boot)
on
the
System
Power
Control
menu
from
the
service
processor
main
menu.
Go
to
″
MAP
0410:
Repair
Checkout
″
in
the
RS/6000
and
Eserver
pSeries
Diagnostic
Information
for
Multiple
Bus
Systems
.
YES
The
boot
attempts
that
follow
will
attempt
to
isolate
any
remaining
I/O
drawer
problems
with
missing
devices.
Ignore
any
codes
that
may
appear
on
the
operator
panel
unless
stated
otherwise.
Go
to
“Step
1540-13”
on
page
118.
Chapter
3.
Maintenance
Analysis
Procedures
117
Содержание RS/6000 Enterprise Server M80
Страница 1: ...RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...
Страница 10: ...x Service Guide...
Страница 14: ...xiv Service Guide...
Страница 16: ...xvi Service Guide...
Страница 22: ...Data Flow 4 Service Guide...
Страница 28: ...CEC Drawer Front View With Bezel Removed 3 2 1 1 Power On Off LED 2 Fan 2 3 Fan 1 10 Service Guide...
Страница 30: ...CEC Card Cage Rear of CEC drawer viewed from top cover removed 12 Service Guide...
Страница 84: ...66 Service Guide...
Страница 176: ...158 Service Guide...
Страница 376: ...358 Service Guide...
Страница 430: ...412 Service Guide...
Страница 445: ...3 Insert the memory module firmly into the connector Chapter 10 Removal and Replacement Procedures 427...
Страница 476: ...7 Remove the screws that connect the carrier to the CD ROM Replacement Replace in reverse order 458 Service Guide...
Страница 485: ...Chapter 11 Parts Information This chapter contains parts information for the system 467...
Страница 486: ...CEC Drawer Card Assembly 9 468 Service Guide...
Страница 488: ...CEC Drawer Backplane 5 2a 1 2 3 4 470 Service Guide...
Страница 490: ...CEC Drawer Power Supplies 1 2 3 4 5 6 7 8 9 472 Service Guide...
Страница 492: ...CEC Drawer Fan Assemblies 2 1 3 4 5 6 8 9 10 11 12 13 7 14 474 Service Guide...
Страница 494: ...I O Drawer 1 2 3 4 5 6 7 8 9 10 11 16 17 18 19 20 12 14 13 13 15 21 22 23 24 26 25 27 476 Service Guide...
Страница 496: ...7 8 9 10 6 1 2 3 4 4 5 478 Service Guide...
Страница 508: ...490 Service Guide...
Страница 520: ...502 Service Guide...
Страница 522: ...504 Service Guide...
Страница 526: ...508 Service Guide...
Страница 542: ...error Handle unexpected modem responses expect 8 r or 7 r or 6 r or 4 r or 3 r delay 2 done 524 Service Guide...
Страница 558: ...540 Service Guide...
Страница 565: ......
Страница 566: ...Printed in USA September 2001 SA38 0571 01...
Страница 567: ...Spine information RS 6000 Enterprise Server Model M80 Eserver pSeries 660 Model 6M1 Service Guide SA38 0571 01...