POST Messages
POST Message
Description
1762
A hard disk configuration error occurred.
Action:
1. Verify that the Configuration/Setup Utility program correctly
reflects the number of hard disk drives that you have
installed. If the drive information is not correct, change it.
(For instructions on using the Configuration/Setup Utility
program, see “Using the Configuration/Setup Utility
Program” on page 28.)
2. If you added or removed a hard disk drive, you must save
the new configuration in the Configuration/Setup Utility
program. See “Using the Configuration/Setup Utility
Program” on page 28 for additional information and
instructions on saving the configuration.
If the problem cannot be isolated and corrected, have the system
serviced.
178X
A failure occurred during testing of the hard disk drive or a
primary or secondary IDE device.
Action:
1. Run the diagnostic programs. (See “Running the Diagnostic
Test Programs” on page 124 for information on running the
diagnostic programs that come with your server.)
2. If the diagnostic programs detect a failure, replace the
defective hard disk drive or primary or secondary IDE
device.
If the problem cannot be isolated and corrected, have the system
serviced.
136
Netfinity 3500 User's Handbook
Содержание Netfinity 3500
Страница 1: ...Netfinity 3500 User s Handbook...
Страница 2: ......
Страница 3: ...Netfinity 3500 User s Handbook IBM...
Страница 8: ...vi Netfinity 3500 User s Handbook...
Страница 14: ...Laser Compliance Statements xii Netfinity 3500 User s Handbook...
Страница 32: ...Input Output Connectors 14 Netfinity 3500 User s Handbook...
Страница 200: ...Replacing the Battery 182 Netfinity 3500 User s Handbook...
Страница 210: ...Ordering Publications 192 Netfinity 3500 User s Handbook...
Страница 250: ...Taiwan Class A Electronic Emission Statement 232 Netfinity 3500 User s Handbook...
Страница 266: ...248 Netfinity 3500 User s Handbook...
Страница 293: ......
Страница 294: ...IBM Part Number 05L2067 Printed in U S A January 1998 5L2 67...