Chapter 3 Operation
3.4 Field Network
Address Map
92
(2) Input and Output Signal Assignment for each Axis
The I/O signals for each axis consists of 2-word for each I/O data register.
● The control signals and status signals are ON/OFF signals in units of bit.
● For the indicated position number and complete position number, 1-word (16-bit) binary data
is available and values from 0 to 511 can be used.
Caution:
Set the operational condition in advance with using a teaching tool such as PC software in the
position number to be used. Selecting a position number with no setting conducted will
generate the alarm code 0A2 “Position Data Error”.
PLC Output (m is PLC output top word address for each axis number)
Address m
b15 b14 b13 b12 b11 b10
b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
Specified
Position No.
–
–
–
–
–
–
–
PC256
PC128
PC64
PC32
PC16
PC
8
PC
4
PC
2
PC
1
Address m+1
b15 b14 b13 b12 b11 b10
b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
Control Signal
BKRL
–
–
–
–
–
–
JOG+
JOG-
–
JISL
SO
N
RES
STP
HOME
CSTR
PLC Input (m is PLC input top word address for each axis number)
Address m
b15 b14 b13 b12 b11 b10
b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
Completed
Position No.
–
–
–
–
–
–
–
PM256
PM128
PM64
PM32
PM16
PM8
PM4
PM2
PM1
Address m+1
b15 b14 b13 b12 b11 b10
b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
Status Signal
EMG
S
CRDY
ZONE
2
ZONE
1
PZO
N
E
MO
DES
WEND
–
–
–
PSFL
SV
ALM
MO
VE
HEND
PE
N
D
1 word = 16 bit
1 word = 16 bit
ME0302-4A
Содержание ERC3
Страница 1: ...IAI Corporation ERC3 Gateway Unit Instruction Manual Forth Edition ...
Страница 2: ......
Страница 4: ...ME0302 4A ...
Страница 8: ...ME0302 4A ...
Страница 35: ...Chapter 1 Specifications Check 1 6 Option 27 1 6 Option はケーブル長 ME0302 4A ...
Страница 54: ...Chapter 2 Wiring 2 3 Wiring Method 46 ME0302 4A ...
Страница 158: ...Chapter 3 Operation 3 8 Field Network LED Indication 150 ME0302 4A ...
Страница 160: ...Chapter 4 I O Parameter 152 ME0302 4A ...
Страница 176: ...Chapter 5 Troubleshooting 5 4 Alarm List 168 ME0302 4A ...
Страница 186: ......
Страница 187: ......