Chapter 3 Operation
3.4 Field Network
Address Map
84
3.4.5
Control Signals for Direct Indication Mode
This is an operation mode to indicate directly with values for the target position, positioning
width, speed, acceleration/deceleration and pressing current.
Set a value to each input and output data register. Set to the parameters when using the zone
signals.
The main functions of ERC3 capable to control in this mode are as described in the following
table.
ROBO cylinder function
: Direct control
△
: Indirect control
: Disabled
Remarks
Home-return operation
Positioning operation
Speed and acceleration/
deceleration setting
Pitch feed (inching)
Pressing operation
Speed change during
movement
Operation at different
acceleration and
deceleration
Pause
Zone signal output
△
Parameters must be set.
PIO pattern selection
(1) PLC Address Composition
(m is PLC input and output top word address for each axis number)
PLC → ERC3 (PLC Output)
ERC3 → PLC (PLC Input)
Target Position
m to m+1
Current Position
m to m+1
Positioning Width
m+2 to m+3
Command Current
m+2 to m+3
Command Speed
m+4
Current Speed
m+4
Acceleration/
Deceleration
m+5
Cannot be used.
m+5
Pressing Current Limit
m+6
Alarm Code
m+6
Control Signal
m+7
Status Signal
m+7
[Refer to Section 3.4.2 for the address maps for each Fieldbus.
Caution : This mode is not applicable for CompoNet, MECHATROLINK and MEC Mode
specifications.
ME0302-4A
Содержание ERC3
Страница 1: ...IAI Corporation ERC3 Gateway Unit Instruction Manual Forth Edition ...
Страница 2: ......
Страница 4: ...ME0302 4A ...
Страница 8: ...ME0302 4A ...
Страница 35: ...Chapter 1 Specifications Check 1 6 Option 27 1 6 Option はケーブル長 ME0302 4A ...
Страница 54: ...Chapter 2 Wiring 2 3 Wiring Method 46 ME0302 4A ...
Страница 158: ...Chapter 3 Operation 3 8 Field Network LED Indication 150 ME0302 4A ...
Страница 160: ...Chapter 4 I O Parameter 152 ME0302 4A ...
Страница 176: ...Chapter 5 Troubleshooting 5 4 Alarm List 168 ME0302 4A ...
Страница 186: ......
Страница 187: ......