Chapter 3 Operation
3.7
About Gateway Parameter Setting
Tool
144
3.7.4 Operation Mode Setting
When selecting the operation mode, select
(Note 1)
the axis number in the pull down menu circled
as 1). By selecting the number, the cells in 2) become blank in response. Click the cell for the
mode to be set in each axis.
If clicking on a blank cell, “*” will appear. “*” indicates that the mode is selected.
Click on a cell with “*”shown in, the mark is changed to “(*)”. “(*)” mark means the axis is treated
as a reserved axis, and even if an error is generated on the actuator, it is available to have
other actuators operated.
(Note 1) Remote I/O Mode cannot be set together with other modes.
1)
2)
ME0302-4A