Chapter 2 Wiring
2.3 Wiring Method
41
2.3.5 Wiring Layout of Fieldbus Connector
Check the instruction manuals for each Field network master unit and mounted PLC for the
details.
1) DeviceNet Type
Connector Name DeviceNet Connector
Cable Side
SMSTB2.5/5-ST-5.08AU
Enclosed in standard
package
Manufactured by
PHOENIX CONTACT
Controller Side
MSTBA2.5/5-G-5.08AU
Pin
No.
Signal Name
(Color)
Description
Applicable cable
diameter
1
V- (BK)
Power supply cable negative side
2
CAN L (BL)
Communication data Low side
3
Shield (None) Shield
4
CAN H (WT) Communication data High side
5
V+ (RD)
Power supply cable positive side
Dedicated cable
for DeviceNet
Note Connect a terminal resistor (121
) between CAN L and CAN H if
the unit comes to the end of the network. [Refer to 2.2 [4] Wiring
Layout of Field Network]
1
2
3
4
5
Shield
BL (CAN L)
RD (V+)
WT (CAN H)
BK (V-)
Front view of
connector on
controller side
ME0302-4A