Chapter 2 Wiring
2.3 Wiring Method
44
4) CompoNet Type
Connector Name
CompoNet Connector
Cable Side
Prepare a connector complied with CompoNet standards.
Controller Side
XW7D-PB4-R
Manufactured by OMRON
Pin
No. Signal Name
Description
Applicable cable
diameter
1 BS+(RD)
Communication power
(Note1)
2 BDH(WT)
Signal line H side
3 BDL(BL)
Signal line L side
4 BS- (BK)
Communication power supply-
(Note1)
CompoNet
Dedicated Cable
Note 1 It is not necessary to supply the communication power. (Internal
power source is used.)
If conducting multi power supply to other slave devices via communication
cables, there is no problem with connecting the power supply to BS+ and
BS- terminals.
Note 2 Connect a terminal resistor (121
) between BDH and BDL if the unit
comes to the end of the network. [Refer to 2.2 [4] Wiring Layout of Field
Network]
5) EtherNet/IP Type
Connector Name
EtherNet/IP Connector
Cable Side
8P8C Modular Plug
Controller Side
8P8C Modular Jack
Pin
No.
Signal Name
(Color)
Description
Applicable cable
diameter
1 TD+
Sent data +
2 TD-
Sent data -
3 RD+
Received data +
4 –
Not used
5 –
Not used
6 RD-
Received data -
7 –
Not used
8 –
Not used
For EtherNet
cable, use a
straight STP
cable that
possesses the
performance of
Category 5 or
more.
Front view of
connector on
controller side
Black
(BS-)
Blue
(BDL)
Red
(BS+)
White
(BDH)
1
8
Front view of
connector on
controller side
1
2
3
4
ME0302-4A
Содержание ERC3
Страница 1: ...IAI Corporation ERC3 Gateway Unit Instruction Manual Forth Edition ...
Страница 2: ......
Страница 4: ...ME0302 4A ...
Страница 8: ...ME0302 4A ...
Страница 35: ...Chapter 1 Specifications Check 1 6 Option 27 1 6 Option はケーブル長 ME0302 4A ...
Страница 54: ...Chapter 2 Wiring 2 3 Wiring Method 46 ME0302 4A ...
Страница 158: ...Chapter 3 Operation 3 8 Field Network LED Indication 150 ME0302 4A ...
Страница 160: ...Chapter 4 I O Parameter 152 ME0302 4A ...
Страница 176: ...Chapter 5 Troubleshooting 5 4 Alarm List 168 ME0302 4A ...
Страница 186: ......
Страница 187: ......