Chapter 1 Specifications Check
1.4 Specifications for each Fieldbus
25
1.4.6 Specifications of EtherNet/IP Interface
Item
Specification
Communication Protocol
IEC61158 (IEEE802.3)
Baud Rate
10BASE-T/100BASE-T (Autonegotiation setting is recommended)
Communication Cable Length
Follows EtherNet/IP specifications (Distance between hub and each node: 100m
max.)
Number of Connection
Master Unit
Available Node Addresses for Setting 0.0.0.0 to 255.255.255.255
Communications Cable
(Note 1)
Category 5 or more
(Double shielded cable braided with aluminum foil recommended)
Connector
RJ45 Connector × 1pc
(Note 1) Prepare a LAN cable separately for the connection cable.
1.4.7 Specifications of EtherCAT Interface
Item
Specification
Communication Protocol
IEC61158 type 12
Physical Layer
100Base-TX (IEEE802.3)
Baud Rate
Automatically follows the master
Communication Cable Length
Follows EtherCAT® specifications (Distance between each node: 100m max.)
Slave Type
I/O slave
Applicable Node Address
0 to 127 (17 to 80: When connected to the master (CJ1W-NC*82) manufactured by
OMRON)
Communications Cable
(Note1)
Category 5 or more
(Double shielded cable braided with aluminum foil recommended)
Connector
RJ45 Connector × 2pcs (Input × 1, Output × 1)
Connection
Daisy chain only
(Note 1) Prepare a LAN cable separately for the connection cable.
ME0302-4A
Содержание ERC3
Страница 1: ...IAI Corporation ERC3 Gateway Unit Instruction Manual Forth Edition ...
Страница 2: ......
Страница 4: ...ME0302 4A ...
Страница 8: ...ME0302 4A ...
Страница 35: ...Chapter 1 Specifications Check 1 6 Option 27 1 6 Option はケーブル長 ME0302 4A ...
Страница 54: ...Chapter 2 Wiring 2 3 Wiring Method 46 ME0302 4A ...
Страница 158: ...Chapter 3 Operation 3 8 Field Network LED Indication 150 ME0302 4A ...
Страница 160: ...Chapter 4 I O Parameter 152 ME0302 4A ...
Страница 176: ...Chapter 5 Troubleshooting 5 4 Alarm List 168 ME0302 4A ...
Страница 186: ......
Страница 187: ......