SmartLogger2000
User Manual
7 WebUI
Issue 04 (2018-04-10)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
182
Figure 7-81
Clearing alarms
By clearing alarms, users can clear all active and historical alarms for the selected device
and enable the SmartLogger to re-collect alarm data.
By clearing alarms, users can clear the local SmartLogger alarms or device storage alarms.
If the version of the SUN2000-(8KTL-28KTL) is earlier than SUN2000 V100R001C81,
users can only clear local SmartLogger alarms by performing the operation.
If
Clear Alarm
is performed for the Huawei devices such as the inverter and PID,
Alarm
Reset
must be performed on the NMS. Otherwise the SmartLogger cannot collect alarm
data from the devices after alarms are cleared.
If
Clear Alarm
is performed for the SmartLogger,
Alarm Reset
must be performed on the
NMS. Otherwise the SmartLogger cannot collect alarm data from the devices after
Alarm
Reset
is performed.
7.11.8.5 Re-collecting Performance Data
You can re-collect previous performance data and energy yield over the WebUI.
This function is not applicable to the SUN2000-(8KTL-28KTL) inverter.
Because of permission restriction, log in as
Advanced User
or
Special User
. Choose
Maintenance
>
Collect Perf. Data
to access the target page.