SmartLogger2000
User Manual
7 WebUI
Issue 04 (2018-04-10)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
105
No. Parameter
Description
Unit
Value Range
Remarks
14
Arc detection
adaptation
mode
Adjusts the sensitivity of
arc detection.
N/A
High
Moderate
Low
This parameter is supported
by the inverters named with
-US
and displayed when
AFCI
is set to
Enable
.
15
AFCI self-test
Send the AFCI self-test
command manually.
N/A
N/A
16
Current error
during scanning
When the IV curves of PV
strings are being scanned,
the current change of PV
strings operating properly
should be monitored to
avoid inaccurate scanning
caused by sunlight
change. If the current
exceeds the specified
value, it is determined that
the sunlight changes, and
the IV curves should be
scanned again.
A
[0.00, 2.00]
N/A
17
OVGR linked
shutdown
If this parameter is set to
Enable
, the inverter shuts
down after receiving the
OVGR signal. If this
parameter is set to
Disable
, the inverter does
not shut down after
receiving the OVGR
signal.
N/A
Disable
Enable
This parameter is displayed
after the Japanese grid code
is selected.
18
Dry contact
function
Identifies the dry contact
signals from the
SmartLogger.
N/A
NC
OVGR
Set this parameter to
OVGR
for OVGR signals, and set it
to
NC
for other signals. This
parameter is displayed after
the Japanese grid code is
selected.
19
Hibernate at
night
The inverter monitors PV
strings at night. If
Hibernate at night
is set
to
Enable
, the monitoring
function of the inverter
will hibernate at night,
reducing power
consumption.
N/A
Disable
Enable
N/A