6-3
Electrical Servicing
(1) 2P (NATURAL) CONNECTOR
(2) DIRECT IGNITION COIL
Removal/Installation
Remove the fuel tank.
Disconnect the direct ignition coil 2P (Natural) con-
nector.
Remove the direct ignition coil from the cylinder
head.
Installation is in the reverse order of removal.
(1) 33P (BLACK) CONNECTOR
(2) PGM-FI/IGN UNIT
Ignition Pulse Generator Inspection
Check the ignition coil resistance at the ECM 33P
(Black) connector (page 6-5).
Connection:
Blue/yellow – Green/black
White/yellow – Green/black
Standard: 180 - 280
Ω
(20˚C/68˚F)
(2)
(1)
(1)
(2)
(1) 6P (NATURAL) CONNECTOR
If the resistance is out of specification, measure the
resistance at the alternator 6P (Natural) connector.
If the measured resistance at ECM 33P (Black) con-
nector is incorrect and the alternator 6P (Natural)
connector is correct, check the wire harness.
If the resistance is still out of standard, replace the
ignition pulse generator/stator assembly (page 4-
64).
(1)