6-2
Electrical Servicing
(1) 5P (NATURAL) CONNECTOR
(2) BOLTS
(3) REGULATOR/RECTIFIER
Regulator/Rectifier Removal/installation
Disconnect the regulator/rectifier 5P (Black) connec-
tor.
Remove the bolts and regulator/rectifier unit.
Install the regulator/rectifier in the reverse order of
removal.
(1) 33P (BLACK) CONNECTOR
(2) PGM-FI/IGN UNIT
Ignition System Inspection
Disconnect the PGM-FI/IGN unit 33P (Black) connec-
tor.
(1) 2P (NATURAL) CONNECTOR
(2) DIRECT IGNITION COIL
Disconnect the direct ignition coil 2P (Natural) con-
nector.
Check for continuity between the direct ignition coil
2P (Natural) connector and PGM-FI/IGN unit 33P
(Black) connector terminals.
Connection:
Yellow/Blue – Yellow/Blue (primary coil)
Black – Black (Ignition)
If there are no continuity, check for wire harness.