Diagnostics
80
5
The backplane failed POSTs (indicated by a 01 FRU code) and must be removed
and replaced (“
■
This procedure is non-concurrent and must be performed while director
power is off.
■
Perform the data collection procedure as part of FRU removal and
replacement.
Did backplane replacement solve the problem?
NO
YES
↓
The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.
6
A CTP card failed POSTs (indicated by a 02 FRU code) and must be removed and
replaced (“
■
This procedure is concurrent and can be performed while director power is on.
■
Perform the data collection procedure as part of FRU removal and
replacement.
Note:
Do not remove and replace a redundant CTP card if the backup CTP card is not
fully operational and director power is on. The director IP address, configuration data,
and other operating parameters will be lost.
Table 8: Byte 0 FRU Codes
Byte 0
Failed FRU
Action
01
Backplane.
Go to
02
CTP card.
Go to
03
SBAR assembly.
Go to
05
Fan module.
Go to
06
Power supply.
Go to
08-0F
UPM card.
Go to
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...