Diagnostics
62
42
At the director, inspect the amber LED at the top of each CTP card.
Is the amber LED illuminated on both CTP cards?
NO
YES
↓
Failure of both CTP cards is indicated. Event codes are not recorded.
Go to “
MAP 0500: FRU Failure Analysis
” on page 107. Exit MAP.
43
A director-to-PC Internet link problem (Internet too busy or IP address typed
incorrectly) is indicated.
1. Wait approximately five minutes, then attempt to log in to the director again.
2. At the Netsite field (Netscape Navigator) or Address field (Internet
Explorer), type
xxx.xxx.xxx.xxx
is the IP address of the director (obtained in
The Username and Password Required dialog box displays.
3. Type the username and password obtained in
, and click OK. If the
View panel does not display, wait another five minutes and perform this step
again.
Is the Embedded Web Server interface operational with the View panel
displayed?
YES
NO
↓
Perform director fault isolation at the HAFM appliance. Go to
44
At the View panel, inspect the Status field.
Does the director status indicate Operational?
NO
YES
↓
The director is operational. Exit MAP.
45
Inspect Fibre Channel port operational states.
1. At the View panel, click the Port Properties tab. The View Port Properties
panel displays, as shown in
2. Inspect the Beaconing and Operational State fields.
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...