Diagnostics
108
420
Backup CTP card NV-RAM failure.
Go to
426
Multiple ECC single-bit errors occurred.
Go to
433
Non-recoverable Ethernet fault.
Go to
440
Embedded port hardware failed.
Go to
604
SBAR assembly failure.
Go to
605
SBAR assembly revision not supported.
Go to
607
Director contains no operational SBAR
assemblies.
805
High temperature warning (SBAR assembly
thermal sensor).
806
Critically hot temperature warning (SBAR
assembly thermal sensor).
807
SBAR assembly shutdown due to thermal
violation.
810
High temperature warning (CTP card thermal
sensor).
811
Critically hot temperature warning (CTP card
thermal sensor).
812
CTP card shutdown due to thermal violation.
Go to
850
System shutdown due to CTP card thermal
violations.
Table 11: MAP 0500: Event Codes (Continued)
Event Code
Explanation
Action