Event Code Tables
370
Event Data:
Byte 0 = UPM slot position (00 through 0F).
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 and 9 = detected module identifier.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
Event Code: 506
Message:
Fibre Channel port failure.
Severity:
Major.
Explanation:
A Fibre Channel port on a UPM card failed. The amber LED corresponding to the
port illuminates to indicate the failure. Other ports remain operational if their LEDs
are extinguished.
Action:
Replace the indicated UPM card with a functional UPM card of the same type.
Perform the data collection procedure and return the backup CD and faulty card to
HP support personnel.
Event Data:
Byte 0 = port number (0-127 and 132-143).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 through 11 = reason code specific.
Byte 16 = connector type.
Bytes 17 and 18 = transmitter technology.
Byte 19 = distance capabilities.
Byte 20 = supported transmission media.
Byte 21 = speed capabilities.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
✔
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...