Diagnostics
142
Advise the customer of the problem and work with the system administrator to
reconfigure the fabric so the path between any two fabric elements does not
traverse more than three hops.
Did fabric reconfiguration solve the problem?
NO
YES
↓
The director and multi-switch fabric are operational.
Exit MAP.
Contact the next level of support. Exit MAP.
11
As indicated by an event code 063, the fabric controller software detected a fabric
element (director or switch) in a multi-switch fabric that has exceeded the number
of recommended ISLs. Fibre Channel frames may be lost or routed in loops
because of potential fabric routing problems.
Advise the customer of the problem and work with the system administrator to
reconfigure the fabric so that no director or switch elements have more than the
maximum number of recommended ISLs. (Please refer to the release notes for the
supported number of interswitch links.) Did fabric reconfiguration solve the
problem?
NO
YES
↓
The director and multi-switch fabric are operational. Exit MAP.
Contact the next level of support. Exit MAP.
12
A 070 event code indicates an E_Port detected an incompatibility with an attached
director and prevented the directors from forming a multi-switch fabric. A
segmented E_port cannot transmit Class 2 or Class 3 Fibre Channel traffic.
A 071 event code indicates the director is isolated from all directors in a
multi-switch fabric, and is accompanied by a 070 event code for each segmented
E_Port. The 071 event code is resolved when all 070 events are corrected.
Obtain supplementary event data for each 070 event code.
1. At the Hardware View, choose Logs > Event Log. The Event Log displays.
2. Examine the first five bytes (0 through 4) of event data.
3. Byte 0 specifies the director port number (0-127 and 132-143) of the
segmented E_port. Byte 4 specifies the segmentation reason (
).
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...