Event Code Tables
387
Event Code: 812
Message:
CTP card shutdown due to thermal violation.
Severity:
Major.
Explanation:
A CTP card failed and was powered off because of excessive heat. This event
follows an indication that the hot temperature threshold was reached or exceeded
(event code 811). If the active CTP card fails, the backup card takes over operation.
If the backup CTP card fails, the active card is not impacted.
Action:
Replace the failed CTP card with a functional card. Perform the data collection
procedure and return the backup CD and faulty card to HP support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
✔
Event Code: 850
Message:
System shutdown due to CTP card thermal violations.
Severity:
Severe.
Explanation:
The director powered off because of excessive thermal violations on the last
operational CTP card.
Action:
Replace the failed CTP card with a functional card. Perform the data collection
procedure and return the backup CD and faulty card to HP support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
✔
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...