Diagnostics
93
↓
.
2
lists event codes, brief explanations of the codes, and associated steps that
describe fault isolation procedures.
3
Is fault isolation being performed at the HAFM appliance?
YES
NO
↓
Fault isolation is being performed through the Embedded Web Server
interface. Go to
.
4
At the HAFM appliance’s Products View, does a grey square display at the alert
panel and as the background to the icon representing the director reporting the
problem?
YES
NO
↓
The director-to-HAFM appliance connection is restored and is
operational. Exit MAP.
The grey square indicates the HAFM appliance cannot communicate with the
director because:
■
The director-to-HAFM appliance Ethernet link failed.
■
AC power distribution in the director failed, or AC power was disconnected.
■
Both of the director’s CTP cards failed.
Continue to the next step.
Table 9: MAP 0400: Event Codes
Event Code
Explanation
Action
430
Excessive Ethernet transmit
errors.
Go to
431
Excessive Ethernet receive
errors.
Go to
432
Ethernet adapter reset.
Go to
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...