FRU Removal and Replacement
260
— Data bits—
8
— Parity—
None
— Stop bits—
1
— Flow control—
Hardware
When the parameters are set, click OK. The HyperTerminal window
displays.
d. At the C> prompt, type the maintenance-level password (the default is
level-2) and press Enter. The password is case sensitive. The
HyperTerminal window displays with a C> prompt at the top of the
window.
e.
Type the command
oem nnnnnnnn
, where
nnnnnnnn
is the original
director serial number recorded in
step 1
or
step 5
of the removal
procedure.
f.
Choose Exit from the File menu to close the HyperTerminal application.
20. Initial machine load (IML) the director. At the front of the director, press and
hold the white IML button on the faceplate of the active CTP card (green LED
illuminated) for three seconds.
21. At the Hardware View, observe all FRU graphics and ensure no alert
symbols display that indicate a failure (yellow triangle or red diamond). If a
problem is indicated, go to “
” on page 45 to isolate the
problem.
22. Perform the data collection procedure (“
23. Perform one of the following to clear the system error (ERR) LED:
— If at the HAFM application, open the Hardware View and:
a.
Right-click the front panel bezel graphic (away from a FRU) to open
a menu.
b.
Click Clear System Error Light.
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...