FRU Removal and Replacement
235
— 501—Port card has been recognized.
If an event code 501 does not display in the log, go to “
” on page 45 to isolate the problem.
9. At the Hardware View, double-click the graphic representing the
replacement card to open the Port Card View. At the Port Card View:
a.
Ensure no alert symbols display that indicate a failure (yellow triangle or
red diamond).
b. Verify that UPM card information (FRU name, position, and state) is
correct.
If a problem is indicated, go to “
” on page 45 to
isolate the problem.
10. Restore communication to the replacement UPM card and set the card online
as directed by the customer (“
” on page 204). Inform the
customer the UPM card is available for use.
11. Perform the data collection procedure (“
12. Perform one of the following to clear the system error (ERR) LED:
— If at the HAFM application, open the Hardware View and:
a.
Right-click the front panel bezel graphic (away from a FRU) to open
a menu.
b.
Click Clear System Error Light.
— If at an EWS interface:
a.
Click the Switch tab at the Operations panel. The Operations panel
displays with the Switch page open.
b.
Click the Sys Err Light tab. The Switch page displays with the Sys
Err Light tab selected. A
System Error Light is ON
message displays on the page.
c.
Click Clear Light.
13. If necessary, close and lock the equipment cabinet door.
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...