Event Code Tables
334
Event Data
Continued:
A = Unauthorized port binding WWN–The device WWN or nickname used to
configure port binding for this port is not valid. Reconfigure the port with the WWN
or nickname authorized for the attached device.
B = Unresponsive node–The attached node did not respond, resulting in a G_Port
ELP timeout. Check the status of the attached device and clean the link’s fiber optic
components (cable and connectors). If the problem persists, contact support
personnel to report the problem.
C = ESA security mismatch–Processing of the Exchange Security Attribute (ESA)
frame detected a security feature mismatch. The fabric binding and director
binding parameters for this director and the attached fabric element must agree.
Ensure the parameters for both fabric elements are compatible or disable the fabric
and director binding features.
D = Fabric binding mismatch–Fabric binding is enabled and an attached fabric
element has an incompatible fabric membership list. Update the fabric membership
list for both fabric elements to ensure compatibility or disable the fabric binding
feature.
E = Authorization failure reject–The fabric element connected to the director
through an ISL detected a security violation. As a result, the director received a
generic reason code and set the port to an invalid attachment state. Check the port
status of the attached fabric element and clean the link’s fiber optic components
(cable and connectors). If the problem persists, contact support personnel to report
the problem.
F = Unauthorized switch binding WWN–Director binding is enabled and an
attached device or fabric element has an incompatible director membership list.
Update the director membership list for the director and the attached device or
fabric element to ensure compatibility or disable the director binding feature.
11 = Fabric mode mismatch–Based on the ELP revision level, a connection was not
allowed because an HP switch in legacy mode is attached to an HP switch in Open
Fabric mode, or an HP switch in Open Fabric mode is attached to an OEM switch
at an incorrect ELP revision level. Update the fabric mode for one switch.
12 = CNT WAN extension mode mismatch–Based on switch-to-switch differences
between the ELP maximum frame sizes allowed, a connection was not allowed to a
switch set to Computer Network Technologies (CNT) wide area network (WAN)
extension mode. Contact Computer Network Technologies for support.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...