Diagnostics
121
13
A link incident may have occurred, but the LIN alerts option is not enabled for the
port and the attention indicator does not display.
At the Hardware View, choose Logs > Link Incident Log. The Link Incident
Log displays. If a link incident occurred, the affected port number is listed with
one of the following messages.
Link interface incident-implicit incident.
Link interface incident-bit-error threshold exceeded.
Link failure-loss of signal or loss of synchronization.
Link failure-not-operational primitive sequence (NOS) received.
Link failure-primitive sequence timeout.
Link failure-invalid primitive sequence received for the current
link state.
Table 13: MAP 0600: Port Operational and LED States
Operational State
Green LED
Amber LED
Action
Offline
Off
Off
Go to
Not Operational
Off
Off
Go to
Testing
Off
Blinking
Internal loopback test in
process.
Exit MAP.
Testing
On
Blinking
External loopback test
in process.
Exit MAP.
Beaconing
Off or On
Blinking
Go to
Invalid Attachment
On
Off
Go to
Link Reset
Off
Off
Go to
Link Incident
Off
Off
Go to
Segmented E_Port
On
Off
Go to
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...