Diagnostics
77
Analysis for an Ethernet link or dual CTP card failure is not described in this
MAP. Go to “
” on page 45. If this is the second time at this
step, contact the next level of support. Exit MAP.
25
Is the Embedded Web Server interface operational?
NO
YES
↓
26
A
Page cannot be found, Unable to locate the server,
HTTP 404-file not found
, or other similar message displays. The
message indicates the Web browser PC cannot communicate with the director
because:
■
The director-to-PC Internet link could not be established.
■
AC power distribution in the director failed, or AC power was disconnected.
■
Both of the director’s CTP cards failed.
Continue to the next step.
27
Ensure the director reporting the problem is connected to facility AC power and
the power switch (circuit breaker) at the rear of the director is set to the ON (up)
position. Inspect the director for indications of being powered on, such as:
■
At the front bezel, an illuminated power LED (green) or system error LED
(amber).
■
An illuminated green LED on the active CTP card.
■
At least one green PWR OK LED illuminated on a power supply.
■
Audio emanations and airflow from cooling fans.
Is the director powered on?
YES
NO
↓
Analysis for an Ethernet link or dual CTP card failure is not described in this
MAP. Go to “
” on page 45. If this is the second time at this
step, contact the next level of support. Exit MAP.
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...