FRU Removal and Replacement
240
Figure 76: UPM filler blank removal and replacement
Replacing the Filler Blank
To replace a filler blank:
1. Remove the filler blank from its packaging.
2. Hold the filler blank by its stiffener and insert it in the chassis card track, as
shown in
3. To secure the filler blank, sequentially insert the torque tool into each locking
Allen screw. Turn each screw clockwise until you feel the torque tool release
and hear a clicking sound. As each screw turns clockwise, the filler blank
locks into place.
4. Verify the filler blank stiffener is flush with the front of the card cage and is
even with other director logic cards.
5. If necessary, close and lock the equipment cabinet door.
1
Torque tool
2
UPM filler blank
2