Information and Error Messages
294
Error Messages
Cannot disable
Insistent Domain ID
while Fabric Binding is
active.
You attempted to
disable the Insistent
Domain ID parameter
through the Configure
Switch Parameters
dialog box, but Fabric
Binding is enabled.
Disable Fabric Binding through
the Fabric Binding dialog box
before disabling these
parameters.
Cannot enable
beaconing on a failed
FRU.
Occurs when selecting
Enable Beaconing
option for a failed
FRU.
Replace FRU and enable
beaconing again or enable
beaconing on operating FRU.
Cannot enable
beaconing while the
system light is on.
Occurs when choosing
Enable Beaconing
option for a failed
FRU.
Replace FRU and enable
beaconing again or enable
beaconing on an operating
FRU.
Cannot enable
beaconing while the
system error light is
on.
Beaconing cannot be
enabled while the
system error light is
on.
Select
Clear System Error Light
from
Product
menu to clear
error light, then enable
beaconing.
Cannot enable Open
Trunking while
Enterprise Fabric
Mode is active and the
switch is offline.
Enterprise Fabric
mode is active and the
switch or director is
online and you
attempted to enable
Open Trunking. This
message only displays
if the optional Open
Trunking feature is
installed.
Perform either of the following
steps:
■
Disable Enterprise Fabric
Mode option by selecting the
appropriate fabric in the
Fabric Tree portion of the
HAFM Manager window
(Fabrics tab) and then
selecting Enterprise Fabric
Mode from the Fabrics
menu. When the Enterprise
Fabric Mode dialog box
displays, click Start and
follow prompts to disable the
feature.
■
Set the switch or director
offline through the Set
Online State dialog box.
Display this dialog box by
selecting Set Online State
from the Element Manager
Maintenance menu.
Table 32: Element Manager Messages (Continued)
Message
Description
Action
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...