Diagnostics
116
1
Was an event code 080, 081, 504, 505, 506, 507, 512, 514, 800, 801, or 802
observed at the director Event Log (HAFM appliance) or at the Embedded Web
Server Event Log?
YES
NO
↓
.
2
Was an event code 581, 582, 583, 584, 585, or 586 observed at the console of an
OSI or FICON server attached to the director reporting the problem?
YES
NO
↓
.
3
lists event codes, brief explanations of the codes, and associated steps
that describe fault isolation procedures.
Table 12: MAP 0600: Event Codes
Event Code
Explanation
Action
080
Unauthorized World-Wide Name.
Go to
081
Invalid attachment.
Go to
504
UPM card failure.
Go to
505
UPM card revision not supported.
Go to
506
Fibre Channel port failure.
Go to
507
Loopback diagnostics port failure.
Go to
512
SFP optical transceiver nonfatal error.
Go to
514
SFP optical transceiver failure.
Go to
581
Implicit incident.
Go to
582
Bit error threshold exceeded.
Go to
583
Loss of signal or loss of synchronization.
Go to
584
Not operational primitive sequence received.
Go to
585
Primitive sequence timeout.
Go to
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...