Event Code Tables
382
Event Code: 605
Message:
SBAR assembly revision not supported.
Severity:
Minor.
Explanation:
The indicated SBAR assembly is not recognized and displays as uninstalled to the
director firmware.
Action:
Ensure the director model supports the operating firmware version. If the firmware
version is supported, replace the SBAR assembly with a functional assembly.
Perform the data collection procedure and return the backup CD and faulty
assembly to HP support personnel.
Event Data:
Byte 0 = SBAR slot position (00 or 01).
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 and 9 = detected module identifier.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
Event Code: 607
Message:
Director contains no operational SBAR assemblies.
Severity:
Severe.
Explanation:
The director firmware does not recognize an installed SBAR assembly.
Action:
Install at least one functional SBAR assembly and power-on reset (POR) the
director.
Event Data:
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...