Event Code Tables
371
Event Code: 507
Message:
Loopback diagnostics port failure.
Severity:
Informational.
Explanation:
A loopback diagnostic test detected a Fibre Channel port failure.
Action:
No action required. An event code 506 is generated if this diagnostic failure results
in a hard port failure.
Event Data:
Byte 0 = port number (0-127 and 132-143).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 through 11 = reason code specific.
Byte 12 = test type.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
Event Code: 508
Message:
Fibre Channel port anomaly detected.
Severity:
Informational.
Explanation:
The CTP card detected a deviation in the normal operating mode or status of the
indicated Fibre Channel port.
Action:
No action required. An event code 506 is generated if this anomaly results in a
hard port failure.