Information and Error Messages
312
Error Messages
Port cannot swap to
itself.
Port addresses entered
in the Swap Ports
dialog box are the
same.
Ensure that address in the first
and second Port Address fields
are different.
Port diagnostics
cannot be performed
on an inactive port.
This displays when
port diagnostics is run
on a port in an
inactive state.
Run the diagnostics on an
active port.
Port speeds cannot be
configured at a higher
rate than the director
speed.
This displays when you
configure a port to 2
Gb/sec and the
director speed is set to
1 Gb/sec.
Set the director speed to 2
Gb/sec in the Configure Switch
Parameter dialog box.
Port numbers must be
in the range of 0 to
xxx.
When configuring
Preferred Paths, source
ports and exit ports
must be in the range of
ports for the switch
being configured.
In the Configure Preferred
Paths dialog box, change the
numbers in the
Source Port
and
Exit Port
fields to fall within the
port count of the switch on
which you are configuring
paths.
Preferred Paths can
not be enabled until
the Domain ID is set to
Insistent. Disable
Preferred Paths, then
configure Switch
Parameters.
If the switch’s domain
ID has not been set to
Insistent, the user is not
allowed to activate the
Preferred Path
configuration with the
Enable Preferred Paths
check box selected.
Close the Configure Preferred
Paths dialog box and click
Configure
>
Operating
Parameters
>
Switch
Parameters
. In the Configure
Switch Parameters dialog box,
click the
Insistent
check box.
R_A_TOV must be
greater than
E_D_TOV.
R_A_TOV must be
greater than
E_D_TOV.
Change one of the values so
that R_A_TOV is greater than
E_D_TOV
Resource is
unavailable.
The specified
operation cannot be
performed because the
product is unavailable.
Verify that the Ethernet
connection between the HAFM
appliance and the director is
up or available.
Resource is
unavailable.
The specified
operation cannot be
performed because the
product is unavailable.
Verify that the HAFM
appliance-to-product link is up.
If the link is up, the HAFM
appliance may be busy. Try the
operation again later.
Table 32: Element Manager Messages (Continued)
Message
Description
Action
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...