Diagnostics
131
Did updating the switch membership lists solve the problem?
NO
YES
↓
The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.
31
A port connection is not allowed because of a Computer Network Technologies
(CNT) wide area network (WAN) extension mode mismatch. Based on
switch-to-switch differences between the ELP maximum frame sizes allowed, a
connection was not allowed to a director set to CNT WAN extension mode.
Contact Computer Network Technologies for support. Exit MAP.
32
The director and attached device are performing a Fibre Channel link reset. This is
a transient state. Wait approximately 30 seconds and inspect port state and LED
behavior.
Did the link recover and resume operation?
NO
YES
↓
The Fibre Channel link and director are operational. Exit MAP.
.
33
A link incident message displayed in the Link Incident Log or in the Link
Incident field of the Port Properties dialog box; or an event code 581, 582, 583,
584, 585, or 586 was observed at the console of an OSI or FICON server attached
to the director reporting the problem.
Clear the link incident for the port.
1. At the Hardware View, right-click the port. A menu displays.
2. Choose the Clear Link Incident Alert(s) option. The Clear Link Incident
Alert(s) dialog box displays, as shown in
Figure 33: Clear Link Incident Alert(s)
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...