Event Code Tables
342
Power Supply Events (200 through 299)
Event Code: 200
Message:
Power supply AC voltage failure.
Severity:
Major.
Explanation:
Alternating current (AC) input to the indicated power supply is disconnected or AC
circuitry in the power supply failed. The second power supply assumes the full
operating load for the director.
Action:
Ensure the power supply is connected to facility AC power, and verify operation of
the facility power source. If the AC voltage does not recover (indicated by event
code 203), replace the failed power supply. Perform the data collection procedure
and return the backup CD and failed power supply to HP support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
✔
Event Code: 201
Message:
Power supply DC voltage failure.
Severity:
Major.
Explanation:
Direct current (DC) circuitry in the power supply failed. The second power supply
assumes the full operating load for the director.
Action:
Replace the failed power supply. Perform the data collection procedure and return
the backup CD and failed power supply to HP support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Director
HAFM appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
✔
✔
✔
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...