Diagnostics
119
■
Perform an external loopback test for the port as part of FRU removal and
replacement.
Did optical transceiver replacement solve the problem?
NO
YES
↓
The director is operational. Exit MAP.
7
A UPM card failed, and the card must be removed and replaced (“
■
This procedure is concurrent and can be performed while director power is on.
■
Verify location of the failed port. For an OSI environment,
show UPM card numbers (0 through15) and port numbers (0-127
and 132-143). For a FICON environment,
UPM card numbers (0 through 15), port numbers (0-127 and 132-143), and
bolded logical port addresses (hexadecimal 04 through 8F).
■
Notify the customer that all ports on the defective card are to be blocked.
Ensure the customer’s system administrator quiesces Fibre Channel frame
traffic through any operational ports on the card and sets attached devices
offline.
■
Perform an external loopback test for all ports on the replacement card as part
of FRU removal and replacement.
■
Perform the data collection procedure as part of FRU removal and
replacement.
Did UPM card replacement solve the problem?
NO
YES
↓
The director is operational. Exit MAP.
Contact the next level of support. Exit MAP.
8
Is fault isolation being performed at the HAFM appliance?
YES
NO
↓
Fault isolation is being performed at the Embedded Web Server
interface. Go to
.
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...