Diagnostics
134
Did the link incident recur?
YES
NO
↓
The attached device, Fibre Channel link, and director are operational.
Exit MAP.
39
The director port reporting the problem is causing the recurrent link incident. The
recurring link incident indicates port or UPM card degradation and a possible
pending failure. Go to
40
A UPM card is not recognized by director firmware because the firmware version
is not supported or the UPM card failed. Advise the customer of the problem and
determine the correct firmware version to download from the HAFM appliance.
Download the firmware (“
Download a Firmware Version to a Director
page 210). Perform the data collection procedure after the download.
Continue to the next step.
41
Did the firmware download solve the problem?
NO
YES
↓
The director is operational. Exit MAP.
A UPM card failure is indicated. Go to
42
Is the Embedded Web Server interface operational?
NO
YES
↓
43
A
Page cannot be found, Unable to locate the server,
HTTP 404-file not found
, or other similar message displays. The
message indicates the Web browser PC cannot communicate with the director
because:
■
The director-to-PC Internet link could not be established.
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...