Diagnostics
78
28
Inspect power supply operational states at the Embedded Web Server interface.
1. At the View panel, click the FRU Properties tab. The View panel (FRU
Properties tab) displays.
2. Inspect the Status fields for both power supplies.
Does the Status field display a
Failed
message for either power supply?
NO
YES
↓
A redundant power supply failed. Go to
The director is operational. Exit MAP.
MAP 0200: POST Failure Analysis
When the director is powered on, it performs a series of power-on self-tests
(POSTs). When POSTs complete, the director performs an initial program load
(IPL) that loads firmware and brings the unit online. This MAP describes fault
isolation for problems that may occur during the POST/IPL process.
If an error is detected, the POST/IPL process continues in an attempt to initialize
the director and bring it online. An event code 400 is displayed when the director
completes the POST/IPL process.
1
Ensure the director reporting the problem is connected to facility AC power and
the power switch (circuit breaker) at the rear of the director is set to the ON (up)
position. Inspect the director for indications of being powered on, such as:
■
At the front bezel, an illuminated power LED (green) or system error LED
(amber).
■
An illuminated green LED on the active CTP card.
■
At least one green PWR OK LED illuminated on a power supply.
■
Audio emanations and airflow from cooling fans.
Is the director powered on?
YES
NO
↓
An AC power distribution problem is indicated, and analysis for the
failure is not described in this MAP. Go to “
” on page 69. Exit MAP.
Содержание StorageWorks 2/140 - Director Switch
Страница 18: ...About this Guide 18 Director 2 140 Service Manual ...
Страница 160: ...Diagnostics 160 Director 2 140 Service Manual ...
Страница 224: ...FRU Removal and Replacement 224 Director 2 140 Service Manual Figure 72 ESD grounding points 1 ...
Страница 262: ...FRU Removal and Replacement 262 Director 2 140 Service Manual ...
Страница 270: ...Illustrated Parts Breakdown 270 Director 2 140 Service Manual ...
Страница 318: ...Information and Error Messages 318 Error Messages ...
Страница 388: ...Event Code Tables 388 Director 2 140 Service Manual ...