ET User’s Guide
5-5
Optimizing Measurements
Increasing Sweep Speed
To Reduce the Amount of Averaging
If averaging has been turned on (it is off in the factory preset condition),
reducing the averaging factor (or turning it off altogether) will increase
the analyzer's measurement speed. Averaging requires multiple sweeps
which increases measurement time. Turning off averaging and using a
narrower system bandwidth may produce faster results.
1. Press
and enter an averaging factor that is
less than the value displayed on the analyzer screen and press
.
2. If you want to turn the averaging off, press
.
To Reduce the Number of Measurement Points
To reduce the number of measurement points, press
and use the front panel knob, the
keys, or the numeric keypad to enter the reduced number.
Generally, as the number of points is decreased, so is the sweep time.
However, other factors will affect the sweep time such as:
• using frequency bands that contain very low frequencies (below
approximately 20 MHz)
• the number of band crossing points encountered in a sweep (at
approximately 1900 MHz, 2310 MHz, and 2620 MHz) (HP 8714ET
only)
• if the MHz/msec rate is above the maximum rate at which the source
can be swept
The following graph shows an example of the relationship between the
number of points, frequency span, and total cycle time. Total cycle time is
defined as the time from the start of the sweep to the start of the next
sweep. This graph was created with data from a setup on an HP 8714ET
using
conditions, except for number of
points and sweep frequencies, as noted on the graph.
AVG
Average Factor
ENTER
AVG
Average on OFF
MENU
Number of Points
PRESET
Factory Preset
Содержание HP 8712ET
Страница 8: ...viii ET User s Guide ...
Страница 17: ...ET User s Guide 1 1 1 Installing the Analyzer ...
Страница 34: ...1 18 ET User s Guide Installing the Analyzer Preventive Maintenance ...
Страница 35: ...ET User s Guide 2 1 2 Getting Started ...
Страница 52: ...2 18 ET User s Guide Getting Started Performing the Operator s Check ...
Страница 53: ...ET User s Guide 3 1 3 Making Measurements ...
Страница 58: ...3 6 ET User s Guide Making Measurements Measuring Devices with Your Network Analyzer Figure 3 3 Block Diagram ...
Страница 118: ...3 66 ET User s Guide Making Measurements Measuring Impedance Magnitude ...
Страница 119: ...ET User s Guide 4 1 4 Using Instrument Functions ...
Страница 129: ...ET User s Guide 4 11 Using Instrument Functions Using Markers Figure 4 6 6 dB Bandwidth Marker Search ...
Страница 131: ...ET User s Guide 4 13 Using Instrument Functions Using Markers Figure 4 7 6 dB Notch Marker Search ...
Страница 134: ...4 16 ET User s Guide Using Instrument Functions Using Markers Figure 4 10 Multi Peak Search Mode ...
Страница 135: ...ET User s Guide 4 17 Using Instrument Functions Using Markers Figure 4 11 Multi Notch Search Mode ...
Страница 137: ...ET User s Guide 4 19 Using Instrument Functions Using Markers Figure 4 12 Marker Statistics Function ...
Страница 139: ...ET User s Guide 4 21 Using Instrument Functions Using Markers Figure 4 13 Marker Flatness Function ...
Страница 141: ...ET User s Guide 4 23 Using Instrument Functions Using Markers Figure 4 14 RF Filter Statistics Function ...
Страница 143: ...ET User s Guide 4 25 Using Instrument Functions Using Markers Figure 4 15 Delta Marker Mode ...
Страница 149: ...ET User s Guide 4 31 Using Instrument Functions Using Limit Testing Figure 4 16 Limit Lines ...
Страница 167: ...ET User s Guide 4 49 Using Instrument Functions Customizing the Display Figure 4 22 The Display Annotation ...
Страница 171: ...ET User s Guide 4 53 Using Instrument Functions Customizing the Display Figure 4 23 Normal Display ...
Страница 172: ...4 54 ET User s Guide Using Instrument Functions Customizing the Display Figure 4 24 Expanded Display ...
Страница 207: ...ET User s Guide 5 1 5 Optimizing Measurements ...
Страница 226: ...5 20 ET User s Guide Optimizing Measurements Measuring Devices with Long Electrical Delay ...
Страница 227: ...ET User s Guide 6 1 6 Calibrating for Increased Measurement Accuracy ...
Страница 235: ...ET User s Guide 6 9 Calibrating for Increased Measurement Accuracy Calibration Choices Figure 6 4 Calibration Choices ...
Страница 266: ...6 40 ET User s Guide Calibrating for Increased Measurement Accuracy Checking the Calibration ...
Страница 267: ...ET User s Guide 7 1 7 Front Rear Panel ...
Страница 269: ...ET User s Guide 7 3 Front Rear Panel Connectors Connectors Figure 7 1 Analyzer Connectors Front Panel ...
Страница 289: ...ET User s Guide 7 23 Front Rear Panel Line Module Figure 7 12 Power Cable and Line Mains Plug Part Numbers ...
Страница 292: ...7 26 ET User s Guide Front Rear Panel Line Module ...
Страница 293: ...ET User s Guide 8 1 8 Hardkey Softkey Reference ...
Страница 395: ...ET User s Guide 9 1 9 Specifications ...
Страница 397: ...ET User s Guide 9 3 Specifications System Performance ...
Страница 443: ...ET User s Guide 10 1 10 Safety and Regulatory Information ...
Страница 449: ...ET User s Guide 10 7 Safety and Regulatory Information Regulatory Information ...
Страница 450: ...10 8 ET User s Guide Safety and Regulatory Information Regulatory Information ...
Страница 451: ...ET User s Guide 11 1 11 Factory Preset State and Memory Allocation ...