![horsch Maestro 16 SX Скачать руководство пользователя страница 63](http://html1.mh-extra.com/html/horsch/maestro-16-sx/maestro-16-sx_operating-instructions-manual_2164097063.webp)
Pneumatic system | 7
60026387 • 01 • 03/2021 • en
63
NOTE
Ø
Allow the PTO-shaft pumps to warm up prior to use in the field for approx.
5 min at idle speed.
Ø
Fasten the pump with the bracket firmly but stress-free to the tractor, other-
wise the pump or the gear could get damaged.
Ø
Observe the maximum rotary speed of 800 rpm to prevent damage to the
gearbox!
PTO-shaft plug-on pump
1. Plug the pump on to the PTO-shaft.
2. Fasten the anti-twist lock. Fix the adjusting rod in the slot and in the bolt for
the upper link without applying any tension. Match height and distance.
Anti-twist lock
The PTO-shaft speed should not be chosen too high. This would result in increased
oil temperature.
Depending on the fertiliser quantity, a speed of 700 rpm may be quite adequate.
When sowing sugar beet without fertiliser, 500 rpm may already be enough.
Once the required fan speeds have been set, one should reduce the PTO-shaft
speed, until the fan speed starts to drop.
Now raise the PTO-shaft speed again by approx. 10%.
Function
The two PTO-shaft pumps power the hydraulic motors for the fans.
The flow control valves (1 / 2) are used to regulate the oil flow and thus the fan
speed.
The oil in the return flow is guided through the cooler and a filter back into the oil
tank.