21. Connect each power cord to the server.
22. Connect each power cord to the power source.
The installation is complete.
To configure the M.2 SATA SSDs, see the HPE Smart Array SR Gen10 Configuration Guide at the
Redundant power supply enablement option
The RPS enablement option supports the installation of two Gen10 Flexible Slot (Flex Slot) power supplies.
Adding a second power supply provides redundant power support to the server if one power supply fails. You do not have
to power down the server before removing or installing a redundant hot-plug power supply.
Kit contents
• Redundant power supply cage
• Power distribution board
Installing the redundant power supply enablement option
Procedure
1. Review the power supply warnings and cautions.
2. Remove the non-hot-plug power supply.
3. Install the RPS enablement option.
Remove the non-hot-plug power supply
Prerequisites
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
Procedure
1.
2.
3.
Release the power cord from the strain relief clip.
Hardware options installation
147
Содержание ProLiant ML350 Gen10
Страница 26: ...SFF drive bay numbering Smart Array controller Tower orientation Rack orientation 26 Component identification ...
Страница 27: ...SFF drive bay numbering SAS expander Tower orientation Rack orientation Component identification 27 ...
Страница 28: ...NVMe drive bay numbering Tower orientation Rack orientation 28 Component identification ...
Страница 31: ...Component identification 31 ...
Страница 33: ...Open the front bezel Procedure 1 Unlock the front bezel 2 Open the front bezel Operations 33 ...
Страница 55: ...10 Secure the rear end of rack rails to the rack columns with the rear shipping screws Operations 55 ...
Страница 178: ...Cable color Description Blue Front I O cable Orange Front USB cable 178 Cabling ...