The capacitor pack is fully charged after the system boots.
Minimum firmware versions
Product
Minimum firmware version
HPE ProLiant ML350 Gen10 Server system ROM
2.00
HPE Smart Array SR controllers
1.90
HPE Smart Array MR controllers
24.23.0-0041
Installing an energy pack
Prerequisites
Before you perform this procedure:
•
Make sure that a Smart Array P-class Gen10 controller is installed.
• Make sure that you have the following items available:
◦
Storage controller backup power cable (ships with the storage controller)
◦
Energy pack option
• If you are installing the HPE Smart Storage Hybrid Capacitor,
verify that the system BIOS meets the minimum
Procedure
1.
2.
3.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4.
Disconnect all peripheral cables from the server.
5.
Do one of the following:
Position the tower server for hardware configuration.
• Server in rack mode:
Extend the server from the rack.
6.
7.
CAUTION: The snap-in latch of the energy pack holder is flexible. However, to avoid damaging this latch, do not
apply too much pressure on this latch when removing or installing the energy pack from the chassis.
134
Hardware options installation
Содержание ProLiant ML350 Gen10
Страница 26: ...SFF drive bay numbering Smart Array controller Tower orientation Rack orientation 26 Component identification ...
Страница 27: ...SFF drive bay numbering SAS expander Tower orientation Rack orientation Component identification 27 ...
Страница 28: ...NVMe drive bay numbering Tower orientation Rack orientation 28 Component identification ...
Страница 31: ...Component identification 31 ...
Страница 33: ...Open the front bezel Procedure 1 Unlock the front bezel 2 Open the front bezel Operations 33 ...
Страница 55: ...10 Secure the rear end of rack rails to the rack columns with the rear shipping screws Operations 55 ...
Страница 178: ...Cable color Description Blue Front I O cable Orange Front USB cable 178 Cabling ...