![GSi JK125P Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/gsi/jk125p/jk125p_user-manual_2275114083.webp)
GSI Group - Laser Division
JK300HP/JK300P/JK125P
Issue 2.0
Pre-installation and User Manual
Part No: 1EA300E01
Page
69 of 172
Text
Key Range
‘Rep Rate’
Value
Shows current value
Enables numeric editing of value.
0 – 1000.0 Hz
‘Ramp Up’
Shows current value
Enables numeric editing of value.
0 - 9.9 sec
‘Ramp Down’
Shows current value
Enables numeric editing of value.
0 - 9.9 sec
‘En.Trip Hi’
Value
Shows current value
Enables numeric editing of value.
0 – 12.34 J
see note below
‘En.Trip Lo’
Value
Shows current value
Enables numeric editing of value.
0 – 12.34 J
see note below
Note
This value is dependent upon the model of
Laser.
6.11 Energy MONITOR screen
6.11.1 Function
Shows the current Energy value in large-format. Continuously updated.
6.11.2 Entry/Exit
Entry from Setup screen.
Exit to Setup screen.
6.11.3 Status Bar
The Status bar is displayed and continuously updated.
Petitioners Canadian Solar Inc. and Canadian Solar (USA) Inc.
Ex. 1025, p. 69