1.15.3 Fibre Installation
•
Ensure that the bend radius limitations (refer to Section 1.15.4) are observed.
•
Avoid sharp or abrasive surfaces.
•
When fitting the fibre cable, ensure that the orientation key in the fibre termination and
the keyway in the fibre receiver are aligned.
•
When fibre cable is run horizontally it is to be supported, or secured, at intervals no
greater than 4m.
•
Lengths of fibre cable subject to movement, particularly in robot applications, must be
carefully routed and supported to maintain curvature above minimum bend radius
throughout all motion. Adjustable spring tensioners or the incorporation of a helix in the
cable route must accommodate motion without imparting excessive twist or to the
conduit.
•
Grouping the cable with stiffer service cables/pipes is permissible but the cable must
not be used as a supporting member for a group of more flexible cables/pipes.
•
Fibre termination must not be subjected to forces caused by dropping, impacting or
collision by heavy objects.
•
Where the fibre input receiver is inside the Laser enclosure, ensure that there is
enough conduit slack between the fibre receiver and the strain relief gland on the
Laser lid. Make sure that there is no induced stress on the fibre termination or the input
receiver.
1.15.4 Minimum Bend Radii
Condition
Min Bend Radius
Handling/Momentary
120mm
Manually coiling/uncoiling.
Threading cable through supports or laying in cable supports.
Attaching to permanent stationary fixings.
Static/long Term
180mm
Processes where Focus Head remains stationary.
Final installed location of cable between Laser and work enclosure
.
Repetitive Flexing/Dynamic
180mm
Pre- or post-process positioning.
In-process movement of cable.
Multi-axis robot motion of Focus Head.
Single-axis gantry type motion of Focus Head.
Inertial acceleration/decelerations of suspended cable.
Winding/unwinding of residual, suspended coils.