![GSi JK125P Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/gsi/jk125p/jk125p_user-manual_2275114062.webp)
GSI Group - Laser Division
JK300HP/JK300P/JK125P
Pre-installation and User Manual
Issue 2.0
Page 48 of 172
Part No: 1EA300E01
Table 4 - SK-603 Basic Machine (M/C) Interface
PIN #
I/O
FUNCTION
PIN #
I/O
FUNCTION
1
PEXT External 24 Vdc
14
PEXT
External 24 Vdc
2
GNDEXT External 0 Vdc
15
GNDEXT External 0 Vdc
3
I
Select Trigger
16
I
Trigger Input
4
I
Select Laser ON
17
I
Select Multishot
5
I
Request Shutter 2
18
I
Request Shutter 1
6
O
Process Cycle Wait
19
O
Remote Ready Status
7
O
Laser ON Status
20
O
Warning Status
8
O
Alarm Status
21
O
SYNC Output
9
O
Shutter Status 2
22
O
Shutter Status 1
10 O
Ext.
Power
Feedback 23 GND
GNDEXT_INT
11
10 Vdc EPC Ext. Power C
24
0 Vdc
EPC Ext. Power Control -
12
25
13
3.7.4.1 Configuration
The Machine Interface laser inputs and laser outputs may be configured as sinking or
sourcing. There are two switches on the M/C interface panel that individually set the inputs
and outputs as sinking or sourcing.
3.7.4.2 Switches in SINK Position
When the I/P switch is set to SINK, the external Controller output must “pull” current through
the laser input. Likewise, when the O/P switch is set to SINK, the external Controller input
must “pull” current through the laser output.
LASER
CONTROLLER
SK603/x
To all I/Ps
+24V
0V
I/P
+24V
To all O/Ps
O/P
SK603/x
0V
0V
50mA MAX
Figure 9 - Sinking Diagram
Petitioners Canadian Solar Inc. and Canadian Solar (USA) Inc.
Ex. 1025, p. 48