GSI Group - Laser Division
JK300HP/JK300P/JK125P
Issue 2.0
Pre-installation and User Manual
Part No: 1EA300E01
Page
49 of 172
3.7.4.3 Switches in SOURCE Position
When the I/P switch is set to SOURCE, the external Controller output must “push” current
through the laser input. Likewise, when the O/P switch is set to SOURCE, the external
Controller input must “push” current through the laser output.
To all I/Ps
I/P
SK603/x
24V
0V
LASER
CONTROLLER
To all O/Ps
O/P
+24
SK603/x
0V
50mA MAX
Figure 10 - Sourcing Diagram
3.7.4.4 Machine Interface Supply
The Machine Interface requires an ex24Vdc power supply capable of delivering
200mA. This power supply is provided to the remote control device by connecting the supply
to the +V/0V laser inputs on the pin allocations shown in Table 4
Petitioners Canadian Solar Inc. and Canadian Solar (USA) Inc.