GSI Group - Laser Division
JK300HP/JK300P/JK125P
Issue 2.0
Pre-installation and User Manual
Part No: 1EA300E01
Page
89 of 172
Possible causes:
1.
Faulty temperature sensor.
2. Loose
connections.
3.
Faulty Cooler Module.
7.5.14 Alarm 3n14: Conductivity Sensor Fault
Meaning:
The coolant conductivity sensor is faulty.
Possible causes:
1.
Faulty conductivity sensor.
2. Loose
connections.
3.
Faulty Cooler Module.
7.6 Power Supply Alarms (Zone 4)
7.6.1 Alarm 4n01 : Power Supply Module communication fault
Meaning:
Power Supply n stopped communicating on the laser control network.
Possible causes:
1.
Incorrect laser type specified.
2.
Power Supply not fitted.
3.
Loose laser control network connections.
4. Re-programming
Power
Supply.
5.
Faulty Power Supply.
7.6.2 Alarm 4n02 : Power Supply Software Error
Meaning:
The power supply control software failed to initialise.
Possible causes:
1.
Faulty power supply.
7.6.3 Alarm 4n03 : Power Supply Negative 15 Volt Fault
Meaning:
The negative 15 Volt supply for the internal power supply control has failed.
Possible causes:
1.
Faulty power supply.
7.6.4 Alarm 4n04 : Power Supply Fan Fault
Meaning:
The power-supply cooling-fan is either running too slowly, or has stopped.
Possible causes:
1.
Faulty power supply (faulty fan).