Text Key
Range
Value
shape
‘Pulse Trig’
Value
Shows current state
Enables selection of state via edit
keys
Internal,
External
‘Trip’ Enable
Value
Shows current state
Enables selection of state via edit
keys
Enabled,
Disabled
‘Modify Shape’
Value
Shows shape # to be
modified
Enables numeric editing of value.
1 - 10
‘Modify Shape’
Fixed text
Accesses the Modify Shape
screens
‘Display
Energy’
Fixed text
Accesses the Energy Monitor
screen
6.9.3 Status Bar
The Status bar is displayed and continuously updated.
6.10 MODIFY SHAPE screens
6.10.1 Function
For defining 2-sector shapes.
All new values have immediate effect.
6.10.2 Entry/Exit
Entry to first screen from Setup screen.
Down-arrow moves between first and second screens.
6.10.3 Title
‘SHAPE {No}’ shows Shape No being edited.
Text
Key Range
‘Height 1’ Value
Shows current value
for Sector 1
Enables numeric editing of value.
0 – 100.0 %
‘Width 1’ Value
Shows current value
for Sector 1
Enables numeric editing of value.
0 – 20.0 ms
‘Height 2’ Value
Shows current value
for Sector 2
Enables numeric editing of value.
0 – 100.0 %
‘Width 2’ Value
Shows current value
for Sector 2
Enables numeric editing of value.
0 – 20.0 ms
Values for both Height 1, Height 2, Width 1 and Width 2 are limited by operation parameters for
maximum power output.