![GSi JK125P Скачать руководство пользователя страница 145](http://html1.mh-extra.com/html/gsi/jk125p/jk125p_user-manual_2275114145.webp)
GSI Group - Laser Division
JK300HP/JK300P/JK125P
Issue 2.0
Pre-installation and User Manual
Part No: 1EA300E01
Page
131 of 172
Refer to Figure 21 for item identification.
Item Action
WARNING
ELECTRIC SHOCK HAZARDS EXIST.
ELECTRIC SHOCK CAN CAUSE SERIOUS OR FATAL INJURY.
1
Ensure Power is switched OFF.
Wait for 2 minutes. This ensures that the capacitors have discharged to a safe level.
CAUTION
Refer to Section 1.15 – Fibre Optic Handling.
2
Unlock and open the laser head lid.
3
Pull back the Blue Protective Cover (item 1) to expose the PIPA Fibre Termination
(item 2).
4
Unscrew, but do not remove, the clamping screw (item 6) to loosen the Retaining
Clamp.
5
Carefully and in a straight line, withdraw the PIPA Fibre Termination (item 2) from
the PIPA Fibre Receiver (item 7).
6
Fit a protective cover (not illustrated) over the PIPA Fibre Termination (item 2).
7
Carefully remove the PIPA Fibre cable from the Laser Head.
8
Place a piece of tape over the exposed end of the PIPA Fibre Receiver (item 7) to
prevent ingress of dirt or moisture.
Petitioners Canadian Solar Inc. and Canadian Solar (USA) Inc.