![GSi JK125P Скачать руководство пользователя страница 155](http://html1.mh-extra.com/html/gsi/jk125p/jk125p_user-manual_2275114155.webp)
GSI Group - Laser Division
JK300HP/JK300P/JK125P
Issue 2.0
Pre-installation and User Manual
Part No: 1EA300E01
Page
141 of 172
Refer to Figure 26 for item identification.
Step
Action
WARNING
ELECTRIC SHOCK HAZARDS EXIST.
ELECTRIC SHOCK CAN CAUSE SERIOUS OR FATAL INJURY.
1
Clean the cover slide holder (item 4) and place in a clean environment.
2
Using Rubber Bulb Puffer, remove dust particles from faces of Cover Slide (item 8).
If Cover Slide (item 8) is damaged or cannot be cleaned sufficiently, replace Cover
Slide.
CAUTION
WEAR PLASTIC GLOVES.
Optical components are fragile and are easily damaged. Extreme care must be
taken when handling optical components. Always handle optical components
in a clean environment.
3
Place Cover Slide (item 8) in a clean environment.
4
Carefully fold a lens tissue into a pad that is just slightly narrower than Cover Slide
(item 8).
5
Dampen tissue using PROPAN-2-OL (or approved cleaner).
Wipe tissue across the full area of Cover Slide (item 8) in a single stroke.
Note
(Do not use multiple passes as it leaves streaks on the slide).
6
Hold Cover Slide (item 8) by the edge and wipe once more in a single straight
movement. Dispose of the pad.
If necessary, make up a new pad and repeat the process until Cover Slide (item 8)
looks clean when viewed as a mirror.
7
Check the cleanliness of Cover Slide (item 8) again.
8
Ensure the cover slide (item 8) is clean.
9
Ensure O-Ring (item 9) is serviceable, replace if damaged.
10
Fit Cover Slide (item 8) in the cover slide holder (item 7).
Ensure O-Ring (item 9) is in position on Focusing Head.
Offer both Cover Slide (item 8) and the cover slide holder (item 7) together to
Focusing Head.
Screw the cover slide holder (Item 7) on to the focussing head secure the cover
slide (Item 8) and O-ring (Item 9) in position
Petitioners Canadian Solar Inc. and Canadian Solar (USA) Inc.
Ex. 1025, p. 141