![GSi JK125P Скачать руководство пользователя страница 169](http://html1.mh-extra.com/html/gsi/jk125p/jk125p_user-manual_2275114169.webp)
GSI Group - Laser Division
JK300HP/JK300P/JK125P
Issue 2.0
Pre-installation and User Manual
Part No: 1EA300E01
Page
155 of 172
Refer to Figure 32 for item identification.
Step Action
WARNING
ELECTRIC SHOCK HAZARDS EXIST.
ELECTRIC SHOCK CAN CAUSE SERIOUS OR FATAL INJURY.
Removal Procedure
1
Ensure the Power is switched OFF.
Wait for 2 minutes. This ensures that the capacitors have discharged to a safe level.
2
Unlock and open the Laser Head lid.
3
Unplug the pointing diode power lead (item 1).
4
Using a 3mm allen key unscrew and remove the screws (item 2) holding the
pointing diode assembly in position.
5
Remove the pointing diode assembly from the shutter.
6
Place some tape over the hole at the rear of the shutter to prevent optics from any
airborne contamination.
Installation Procedure
CAUTION
If a blanking plate is fitted on the shutter assembly, using screws (item 2),
please remove before installing the pointing diode assembly. Unplug
pointing diode flying lead (item 5) from the blanking plate.
OR
Remove any tape covering the hole at the rear of the shutter assembly.
1
Fit screws (item 2) into pointing diode assembly.
2
Offer both pointing diode and screws (item 2) together to shutter assembly.
3
Locate and tighten the screws (item 2) to hold the pointing diode into position using
a 3mm allen key.
4
Refer to section 9.16.3 and carry out the pointing diode alignment procedure.
Petitioners Canadian Solar Inc. and Canadian Solar (USA) Inc.