GSI Group - Laser Division
JK300HP/JK300P/JK125P
Issue 2.0
Pre-installation and User Manual
Part No: 1EA300E01
Page
33 of 172
2.7 Safety
Control
System
2.7.1 Safety Category
A Laser Safety Officer must be appointed to specify the level of safety precautions and
control to be implemented during normal operating and maintenance work.
At all times a Laser must be operating in a controlled area, appropriate to the level of hazard
it represents.
Note
If a Class 1 enclosure is breached for servicing or maintenance work, and the Laser is in a
Class 4 environment, appropriate controls must be specified.
2.7.2 Safety Compliance
The following standards apply to Laser safety:
Worldwide:
IEC 60825-1: 2001
Europe:
EN 60825-1: 2001
North America:
FDA
Regulation 21 CFR Chapter J 1040.10.
2.7.3 Safety Labelling
Safety labels are fitted to the equipment in compliance with IEC regulations.
Before operating on any part of the Laser system, the hazard level must be checked by
examining the following labels:
•
Safety and Compliance labels - refer to Drawing EE13801DD.
•
Label Locations - refer to Drawing M202439.
The following Class 4 (IV) information appears on label A, on drawing EE13801DD.
MAXIMUM OUTPUT:
1kW/5mW
PULSE
DURATION:
CW
WAVELENGTH:
1064/635nm
This information is supplied for safety purposes only and serves principally to assist in the
selection of suitable protective eyewear and guarding, including integral viewing panels.
These values reflect an appropriate safety margin.
Labels must not be defaced or removed. Damaged or missing labels must be replaced
immediately by contacting GSI Group - Laser Division quoting the label identification
reference given on each label.
Customers must ensure any component fitted has the correct labelling (refer to GSI Group -
Laser Division).
Petitioners Canadian Solar Inc. and Canadian Solar (USA) Inc.
Ex. 1025, p. 33