![GSi JK125P Скачать руководство пользователя страница 112](http://html1.mh-extra.com/html/gsi/jk125p/jk125p_user-manual_2275114112.webp)
GSI Group - Laser Division
JK300HP/JK300P/JK125P
Pre-installation and User Manual
Issue 2.0
Page 98 of 172
Part No: 1EA300E01
7.12.2 Warning 4n02 : Dumping Current
Meaning:
The Power Supply is dumping current following a shutdown.
Reset when current level falls below the threshold.
7.12.3 Warning 4n03 : Dump Resistors Cooling
Meaning:
The Power Supply has been restarted and stopped multiple times, building up heat in the
dump resistors, which requires dissipating before allowing a further restart.
Reset when accumulated cooling time has elapsed.
7.13 Shutter Warnings (Zone 5)
7.13.1 Warning 5n01 : Fibre Temperature
Meaning:
The fibre temperature switch has overheated.
Requires laser (alarm) reset to clear.
7.13.2 Warning 5n02 : Shutter Temperature
Meaning:
The shutter housing temperature switch has overheated.
Requires laser (alarm) reset to clear.
7.13.3 Warning 5n03 : FCMS
Meaning:
The fibre continuity circuit has broken.
Requires laser (alarm) reset to clear.
7.13.4 Warning 5n04 : External Work Chamber Doors
Meaning:
The work chamber doors failed to close simultaneously.
Requires laser (alarm) reset to clear.
7.13.5 Warning 5n05 : Close
Meaning:
The shutter failed to close within specified time.
Requires laser (alarm) reset to clear.
7.13.6 Warning 5n06 : Open
Meaning:
The shutter failed to open within the specified time.
Requires laser (alarm) reset to clear.
Petitioners Canadian Solar Inc. and Canadian Solar (USA) Inc.
Ex. 1025, p. 98